Fikes clean agent system with fm200 also known as hfc227ea, uses fikes patented rupture disc valve design offering additional flexibility. The specification and data sheets for the fm 200 system are located at fike download. This type of fire suppression system is usually used in. Medical facilitiesups roomstelecommunication facilitiescomms roomsdata centres what advantages are. Fm 200 is an important part of an environmentally responsible clean agent fire suppression solution with a zero ozonedepleting potential. The grabcad library offers millions of free cad designs, cad files, and 3d models. However, without performing proper maintenance or inspections on your fire suppression system, the fm 200 system may not activate properly when there is a fire, leaving your business in shambles. Clean agent fire extinguishing system hfc227ea, fm200 fike. Mission fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. The conversion factor is based on extinguishing concentration and ambient room temperature. Fm 200 design concentration engtips engineering forums. Pipe and fittings used in clean agent system piping network must conform to the requirements as outlined in iso 14520, latest editions. Explore fikes comprehensive explosion and fire protection services and our oncampus testing facilities that support product development and customer services. Fm200 suppression systems historically, the most widely used halon 1 replacement, fm200 provides waterless fire suppression without leaving behind residue or particulate, and has been installed in over one hundred thousand applications in more than 70 nations.
The clean agent is retained in the container by a impulse valve assembly which contains a fastacting rupture disc. B the system shall provide an fm200 minimum design concentration of 7. If you need a fire suppression system that will prevent disastrous fires before they get started, have a fm 200 fire suppression system installed by fireline corporation. Computer room saved by fikes fm200 fire suppression system. After an fm 200 system discharge, the fm 200 cylinders should be returned to an authorized.
It takes into account length of pipe, discharge nozzle orifice size, amount of nitrogen to push the gas, etc. As the fastest waterless fire protection system available, protecting your business with the fm 200 system will result in less damage, less need for repairs, and increased safety for your. Our reputation is built on customerfocused engineering solutions, completed on schedule and at competitive rates. Ssi offers hfc227eafm200 clean agent fire suppression systems through our quality line.
Fm200 fm200 is a registered trade mark of the du pont system in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release engineered hydraulic flow program used to predict the two phase flow of fm200 through a pipe network contacts. Design, installation maintenance manualfm200fike gases. Exposure controlspersonal protection engineering control measures use with adequate ventilation. Fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. Fike fm 200 fire suppression systems the fm 200 fire suppression system is designed to extinguish flammable liquids and electrical fires within 10 seconds. The physical and chemical properties of fm 200 are not the same as btm. Fikes engineering provides cost effective mechanical engineering and project management services for your turnkey project, project segment, or to supplement your current inhouse engineering capabilities. Design, installation maintenance manualfm200fike free download as. Introduced to the market in 2004 by fike, ecaro25 is an electrically. Fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. Fm200 and ecaro25 software packages have been updated to include the impulse valve equivalent lengths as well as new container part numbers. The preengineered concept minimizes the amount of engineering involved in the units design. Fm 200 fire suppression system orr protection systems. Fm200 clean agent fire suppression system hfc227 fike.
Join the grabcad community today to gain access and download. Now, fike expands its clean agent offering with the addition of impulse. Piping materials, supports and spacing, must conform to the requirements as outlined in, iso 14520. Vision to eliminate catastrophic loss of life and assets for companies around the world. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems. Fikes fm200 fire suppression system is a clean agent system with fikes impulse valve technology.
The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. They are effective for total flooding protection against hazards involving liquid. Fike fm 200 clean agent fire suppression system with the shp pro control panel fm 200 system w shp pro specification page 2 of 8 pn. Ensure adequate ventilation, especially in confined areas. Fm200 fire suppression system by fike bfpe international. Bosch security conventional fire panel 500 series basics of fire detection duration. Fike fm200 clean agent fire suppression system with the shp pro control panel fm200 system w shp pro specification page 2 of 8 pn. You can find more information about registering here. Fm 200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. Utilization of smaller diameter piping over longer distances equates to this system being 15% more efficient than fm. All physical devices that are a part of the fire detection and suppression system are connected to the control panel including the fenwal analaser, the tyco sprinklers, the rooms hvac units and cpcc systems. To determine the final concentration, flow calculations are required utilizing the particular manufacturers software.
When the discharge tubing and nozzles are installed within the limitations stated in this. And it discharges in 10 seconds or less, extinguishing a fire quickly and. This course is intended for those who design, configure and maintain fike co2 systems. Fm200 gaseous suppression system fire extinguishing fire. Often fm 200 systems are employed to protect critical installations formerly protected by halon 1. This makes it a suitable choice for new installations using total flooding systems, and for halon 1 replacement applications. January, 2008 3 the installing contractor must have a minimum of five 5 years experience in the design, installation and testing of clean agent, or similar, fire suppression systems. The kidde flow calculation software for engineered suppression systems is a sophisticated calculation routin e for predicting the flow of an agent through a pipe network system. For fm 200 fire suppression system services in the houston area, call 78931090 or contact us online. Late on the evening of september 24th, brsintrons it manager, anders stenberg, received a message that the fm 200 extinguishing system in the computer room had been activated. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Computer room saved by fikes fm200 fire suppression. Fm200 systems fire protection services houston, tx. Fike is more than just an industrial safety products manufacturing company.
Halon 1 btm is an effective fire suppressant and has been widely used in total flooding gas protection system. When you consider the potentially devastating environmental effects of an uncontrolled fire, its easy to see that an fm 200 system is an important tthhheef 0ffmm2220000 dddiiiffffeeerrreeennnccceee fm 200 systems reach extinguishing levels in 10 seconds or less, stopping. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. Costeffective protection for highvalue assets highvalue assets such as data and sensitive equipment demand the quality fire suppression offered by the ansul fm200 fire suppression system. After receiving the fire signal, fm 200 is discharged totally from the cylinders within 10 seconds to fill up the space uniformly at the design concentration to extinguish the fire. The ansul fm 200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Unboxing and startup of my new fire alarm control panel firelite ms4 conventional panel. Product overview fm200 fire suppression system clean agent power protects people and property n nonconductive and will not shortout electronic equipment or thermally shock detects fire in early stages n suppresses class a, b and c fires n less visual obscuration and minimal risk to personnel n colorless, odorless clean agent leaves no residue n electrically nonconductive.
It is a waterless fire protection system thats released into the risk inside a 10 second time frame. Installation of brsintrons fm 200 system was quickly and efficiently handled by local fike distributor, exting ab. Impulse technology efficient and cost effective as with previous fike systems, the impulse valve technology continues to allow for a flexible, modular design not available with traditional. Safety data sheet fm200 fire extinguishing agent with. Fike fm200 fire suppression systems the fm 200 fire suppression system is designed to extinguish flammable liquids and electrical fires within 10 seconds. Fm 200 design concentration cdafd specifierregulator 1 dec 05 08. Also people do not have to be worried about being exposed to or breathing in the fm 200 gas. Fm200 gaseous suppression system fire extinguishing.
However, smaller containers that are located in a subfloor space, under a computer bank, or. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Aug 25, 2000 fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. The clean agent fire master 200 fm 200, heptafluoropropane is widely used as a substitute for halon. Through extensive engineering and testing, fike has designed a state. If you are a fike employee, representative, distributor or a preauthorized architectengineer, you may access this site. Revised software packages will be available for free download on the fike technical support website. The windowsbased user interface provides a convenient, fast, and userfriendly method for entering information about the system. Jun 27, 2012 the fm 200 discharge has a zero ozone depletion rate. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. Fires are immediately suppressed by the agent, which otherwise known as hfc227ea. What is fm200 fire suppression and what are its advantages.
Explore fike s full line of fire alarm, fire detection and control, and clean agent and waterbased fire suppression solutions to keep people and assets safe. To schedule fm 200 system services in the new jersey or delaware area, contact confires online or call 888 2280917. Fm200 suppression systems historically, the most widely used halon 1 replacement, fm 200 provides waterless fire suppression without leaving behind residue or particulate, and has been installed in over one hundred thousand applications in more than 70 nations. Fm 200 is an odorless, colorless, liquefied compressed gas.
Fm 200 total flooding fire suppression system general the fm 200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Worldclass fire protection needed for a fullservice computer company. In light of the covid19 pandemic, fike corporation is taking the following measures to protect our employees and business partners from the virus, limit the spread of the virus in our global communities, and continue to support your business with essential lifesafety products and services. Learn how fike has the capabilities, services and products to help your facility reach nfpa 652 compliance, protecting your people and processes from combustible dust explosions. Jul 02, 2007 with fm 200 gas, a combination of physical and chemical mechanisms combine at the surface of the fire to quickly and efficiently kill the flame. Flow calculation software for engineered suppression systems. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. Fikes clean agent system uses fikes patented rupture disc valve design offering additional flexibility, effectiveness and speed. That translates into minimal equipment facility damage and little or no business interruption. Fm 200 1,1,1,2,3,3,3heptafluoropropane, cf3chfcf3 is a colorless odorless gas, low in.
Fike protection systems has conducted extensive testing over the past several years and has developed the necessary knowledge to incorporate fm 200 into its fire suppression system product line. The thickness of the piping wall shall be calculated in accordance with asme b31. Fm 200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. If you have already registered on this site and have had your registration validated. Fm200 fire suppression systems protect everything from computer rooms data. In this 2day course, you will learn how to design, configure, install and maintain a fm 200 hfc227 suppression system. Activation of fire suppression system raises alarm. Fike s clean agent system with fm200 also known as hfc227ea, uses fike s patented rupture disc valve design offering additional flexibility, effectiveness and speed. The atmospheric lifetime of fm 200 has been determined to be 36.
Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. Fike s clean agent system with fm 200 also known as hfc227ea, uses fike s patented rupture disc valve design offering additional flexibility, effectiveness and speed. We provide an immediate response to clean agent fire suppression system discharges, whether accidental or from a fire, to get your system back into service as quickly as possible. Fike products rupture discs, fire suppressant, explosion. The benefits of a fm200 fire suppression system fireline. Personal protective equipment respiratory protection. General and local exhaust ventilation is recommended to. Data sheet agent storage containers with hfc227ea description fike clean agent containers are used in fire extinguishing systems to store the clean agent until a fire develops and the agent must be released. Clean agent fire suppression with workspace technology. Kidde ads series fm 200 fire suppression systems youtube. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is. There should be local procedures for the selection, training, inspection and maintenance of. Abdul rafea alanzi design engineer fike safety technology. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems.
1419 153 1272 496 284 977 714 940 129 109 1114 1463 247 262 1149 856 1434 378 880 366 593 975 583 447 1129 1365 285 1075 167 1443 660 316 1132 429 251 331 1450